Mass Spectrometers for Catalysis & Thermal Analysis Applications

Catalysis Thermal Analysis

Hiden Analytical has been designing and developing the highest quality quadrupole mass spectrometer based gas analysis systems since 1981. They built a reputation for delivering instruments with superior sensitivity, accuracy, and reproducibility, together with a first class global service and applications support network. From dedicated triple filter UHV TPD quadrupoles to fully integrated catalysis microreactor and mass spectrometer systems, Hiden has developed a range of analytical mass spectrometers that address the most advanced and demanding applications.

Download Catalog

Applications

  • Thermal analysis TA/MS
  • Catalysis
  • Fuel cells
  • CVD / MOCVD / ALCVD
  • Surface science
  • Surface analysis
  • Nanotechnology
  • Molecular beam studies

CATLAB-PCS

A system for catalyst characterization, reaction testing, kinetic and thermodynamic measurements.

CATLAB-PCS
  • Fast response, low thermal mass furnace with integrated air-cooling
  • 1-20 °C / min heating rates up to 1000 °C
  • Hiden’s unique interchangeable Catalyst Cartridge System
  • Close-coupled hotzone evolved species probe & direct QIC inlet for <500 ms response
  • ‘In-Bed’ thermocouple for direct catalyst temperature measurement
  • Automatic 2-4 (8 optional) gas stream manifold or combined gas /vapor manifold
  • Independent Mass Flow control of each channel at 3-100 ml/min (other flow options available)
  • Corrosion resistant manifold configurations also available
  • Seamless online, real-time studies with data acquisition and PC analysis
  • Air thermostat and trace heating to minimize condensation of liquid feeds / products
  • Shut-off / bypass flow configuration to seal reactor and gas sampling port

CCATLAB-FB

Horizontal Furnace/MS System for Catalyst Core Quantification.

CCATLAB-FB
  • Fast response, low thermal mass furnace with integrated air-cooling
  • 1-20 °C / min heating rates up to 1000 °C
  • Hiden’s unique interchangeable Catalyst Cartridge System
  • Close-coupled hotzone evolved species probe & direct QIC inlet for <500 ms response
  • ‘In-Bed’ thermocouple for direct catalyst temperature measurement
  • Automatic 2-4 (8 optional) gas stream manifold or combined gas / vapour manifold
  • Independent Mass Flow control of each channel at 3-100 ml/min (other flow options available)
  • Corrosion resistant manifold configurations also available
  • Seamless on-line, real-time studies with data acquisition and PC analysis
  • Air thermostat and trace heating to minimise condensation of liquid feeds / products
  • Shut-off / bypass flow configuration to seal reactor and gas sampling port

HPR-20 TMS

A specialist gas analysis system for fast event transient analysis.

HPR-20 TMS
  • 0.9 m fast response QIC capillary – 150 ms response time
  • Open ion source and optimised pumping configuration for fast response
  • Digital PIC detector – 7 decades continuous log scale
  • Detection of low ppm to high % levels in < 200 ms

HPR-20 EGA

A compact bench-top gas analysis system for evolved gas analysis in thermogravimetric mass spectrometry, TGA-MS.

HPR-20 EGA
  • Enhanced pumping for light gases
  • Heated inlet for non-tailing response to desorbed gases and vapours
  • Control of ionisation energy parameters for simplification of cracking patterns
  • Custom, low dead volume interface to specific manufacturers’ TGA systems
  • Optimised data acquisition using EGAsoft
  • Mass range option 300 or 510 amu

SpaciMS

A system for determination of intra catalyst reactor chemistry

SpaciMS
  • 16 Capillary inlet system
  • Software controlled sampling stream position
  • Z-Drive for positioning of inlet positions
  • Thermocouple inputs for temperature measurement at sampling point
  • Minimally invasive
  • 3-D Mapping of intra-reactor gas composition
  • High temporal distribution

TPD Workstation

A system for UHV temperature programmed desorption (TPD/TDS) studies

TPD Workstation
  • Hiden 3F PIC Mass Spectrometer for fast data acquisition (>500 data points per second)
  • Multiport UHV chamber for attachment of additional instrumentation (e.g. Ellipsometry)
  • Linear sample transfer mechanism and loadlock, including gate valve and viewport
  • Heated sample stage to 1000 °C
  • Z-drive for optimum sample/detector positioning
  • Bakeout Jacket (200 °C max)
  • Integrated Software control of experimental protocols

3F-PIC

A specialist gas analysis system for fast event UHV studies

3F-PIC
  • Low profile ion source
  • Fast data acquisition
  • 500 data points per second
  • Wide dynamic range
  • 7 decade continuous log scale
  • Gating input for pulsed gas studies down to 100 nano seconds gating resolution

HPR-40 DEMS

Solutions for Dissolved Gas Analysis and Off-gas Analysis in Electrochemistry.

HPR-40 DEMS
  • Analysis of dissolved species with mass range 200 amu (300 amu option)
  • Vitreous Carbon – User coatable working electrode
  • Replaceable nanoporous membrane
  • 4 Ports for additional electrodes